AVR
-
Basler AVR, Marathon AVR, Mecc Alte AVR
Caterpillar AVR VR6 | Original
- Power: Shunt Excited
- Input: 180-280 Vac, 50/60 Hz, 1 OR 3 phase
- PMG Excited 63-105 Vac 100/240 Hz 3 phase
- Sensing input: 180-240 Vac, 50/60 Hz 1 OR 3 phase
- CT input: 1 or 5 Aac 50/60 Hz
- ACC input: +/- 3 Vdc. Output 65 Vdc @ 12 Adc
- Unit Type: Potted – Rugged
- Weight: 1.5 kgSize: 9.4 in x 7.1 in x 3.5 in
- 4 mounting holes
- 1 Year Warranty
Call for Quote for international purchases!
SKU: VR6 -
Leroy Somer AVR
Leroy Somer AVR R438 | Original
Fuse: F1on X1,X2.10A;slow-250V
- Voltage sensing : 5 VA isolated via trans- former • 0-110 V terminals = 95 to 140 V • 0-220 V terminals = 170 to 260 V • 0-380 V terminals = 340 to 520 V for other voltages, a transformer should be used.
- Voltage regulation ± 0.5%
- Normal or rapid response time via jumper ST2 (see below)
- Voltage adjustment via potentiometer P2 or apply a DC voltage of ± 1 V on the terminals of the external potentiometer
- Current sensing: (parallel operation): input S1, S2 intended for 1 C.T. Š 2.5 VA cl1, secondary 1A (optional)
- Quadrature droop adjustment via potentio- meter P1
Call for Quote for international purchases!
SKU: R438 -
Leroy Somer AVR
Leroy Somer AVR R448 | Original
- Voltage regulation ± 0.5%
- Short circuit capability: 3 x Irated for 10 seconds (AREP or PMG excitation)
- Voltage sensing: 95 to 140 volts (50/60 Hz) or 170 to 260 volts (50/60 Hz) or 340 to 520 volts (50/60 Hz)
- Response time: Normal (1 sec) for ± 20% voltage variation or Rapid (0.3 sec) for ± 20% voltage variation
- Remote voltage adjustment range of: ± 5%
Call for Quote for international purchases!
SKU: R448 -
Leroy Somer AVR
Leroy Somer AVR R449 | Original
The regulator includes:
- A main terminal strip (10 terminals)
- A secondary terminal block (5 terminals)
- A frequency selection terminal block (3 terminals) – A quadrature droop potentiometer
- A voltage potentiometer
- A stability potentiometer
- A maximum excitation potentiometer
- A sensing selection jumper ST1 (single/3-phase with an external module)
- A response time jumper ST2 – A frequency selection jumper ST3 – An external voltage setting jumper ST4 – A LAM (load adjustment module) jumper ST5
- From R449 Version E number 10,000, this jumper will be removable.
- A selecti
Call for Quote for international purchases!
SKU: R449 -
Leroy Somer AVR
Leroy Somer AVR R450 | Original
The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers.
- Operating temperature: – 30°C to + 65° C. – Storage temperature: – 55°C to + 85°C.
- Shocks on the base: 9 g depending on the 3 axes.
- Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g.
Call for Quote for international purchases!
SKU: R450 -
Leroy Somer AVR
Leroy Somer R250 | Original
- Power Input: AC 80-140V (50 / 60Hz)
- Maximum output: DC 90V / 6A / 10S
- Detection voltage input: AC 115V
- Voltage regulation rate: ≤ ± 1% External voltage trimming 1K / 2W potentiometer ± 10%
- Voltage regulation +/- 0.5% at steady state and constant speed
Call for Quote for international purchases!
SKU: R250 -
Basler AVR, Marathon AVR, Mecc Alte AVR
Mecc Alte AVR SR7-2G (SR-7) | Original
- Sensing Input: Terminal 1,2 3,4 5,6 Can be connected to Y or 220~480VAC Single Phase 50/60HZ.
- Power Input:50~280VAC (1,2) 50/60HZ.
- Output Voltage: Maximum 90VDC @ 220VAC Harmonic Wave. Output Current: Continuous 6A Maximum 8A for 10 sec.
Call for Quote for international purchases!
SKU: SR72G -
-
Uncategorized
Stamford AVR MX321 | Original
Features include:
- Stability selection & adjustment *Under frequency roll off adjustment
- Dip adjustment *Dwell adjustment
- Droop adjustment *Trim adjustment
- Over excitation adjustment *Over voltage adjustment
- Current limit adjustment *Ramp adjustment
Call for Quote for international purchases!
SKU: MX321 -
-
Automatic and manual with Controller
Transfer Switch 2 pole | 125 Amps | TCS2P125-22
- Manufactured using UL 94V-0 plastics.
- Electrically operated and mechanically held.
- Coil operating voltage: 110 / 220 Vac +/- 20%.
- Monitor Normal & Standby source OV and UV.
- Compact size, light weight and low power consumption.
- Adjustable time delay in OFF position when transferring.
- Designed for cell-phone repeaters, and many industrial and home ATS applications.
- Electrically or manually operated, mechanically held contacts – (Open Transition) with adjustable time in neutral.
Call for Quote for international purchases!
SKU: TCS2P125-22 -
Automatic and manual with Controller
Transfer Switch 3 pole | 125 Amps | TCS3P125-22
- Manufactured using UL 94V-0 plastics.
- Electrically operated and mechanically held.
- Coil operating voltage: 110 / 220 Vac +/- 20%.
- Monitor Normal & Standby source OV and UV.
- Compact size, light weight and low power consumption.
- Adjustable time delay in OFF position when transferring.
- Designed for cell-phone repeaters, and many industrial and home ATS applications.
- Electrically or manually operated, mechanically held contacts – (Open Transition) with adjustable time in neutral.
Call for Quote for international purchases!
SKU: TCS3P125-22