SENSING and POWER INPUT
Voltage: 100 – 264 V ac 1 phase
Frequency: 50-60 HZ nominal
OUTPUT
Voltage: 82V d.c. @ 200 Va.c. entrada de energía.
Voltage: 45V d.c. @ 110 Va.c. entrada de energía.
Current: Continuous 5A (see note 1)
transient 7.5A for 10 secs.
Resistance: 15 ohms min
REGULATION
+/- 1.0% (see note 2)
THERMAL DRIFT
0.03% per deg. C change in AVR ambient (see note 3)
TYPICAL SYSTEM RESPONSE
AVR response 20ms
Field current to 90% 80ms
Machine Volts to 97% 300ms
EXTERNAL VOLTAGE ADJUSTMENT
+/-10% with 1 k ohm 1 watt trimmer (see note 4)
Increasing resistance lowers voltage.
Fixed 15kOhm resistor enables 110V sensing
UNDER FREQUENCY PROTECTION
Set point: 94 – 98% HZ (see note 5)
UNIT POWER DISSIPATION
12 watts maximum
BUILD UP VOLTAGE
4 Volts @ AVR terminals
QUADRATURE DROOP INPUT
10 ohms burden
Max. sensitivity: 0.07 a for 5% droop 0PF
Max. input: 0.33 A
OVER EXCITATION PROTECTION
Set point: 67 Vdc +/-3% (fixed)
Time delay: 10 – 15 seconds (fixed)
ENVIRONMENTAL
Vibration: 20 – 100 Hz 50mm/sec
100Hz – 2kHz 3.3g
Operating temperature: -40 to +70C (note 6)
Relative Humidity 0-70C 95% (note 7)
Storage temperature -55 to +80C
NOTES
- De-rate by 20% if mounted external to generator.
- Inclusive of 4% engine governing.
- After 2 minutes warm-up.
- Generator de-rate may apply. Check with factory.
- Factory set, semi,sealed, jumper selectable.
- Non condensing.