Linear Actuator 12V DC | 24V DC • Light-Force (Low-Current Optimized PID)
- Isochronous operation
- No magnetic speed pickup required
- For Genset only – 260 V AC MAX
- Rugged hard potted design
- Gain and stability adjustments
- Lower system cost
The speed signal input must be in the frequency range of 40 to 80 Hz. Other features include:
$250.77
Linear Actuator 12V DC | 24V DC • Light-Force (Low-Current Optimized PID)
Performance
| Isochronous Operation | ± 0.25 % |
| Speed Range | 40 – 70 Hz |
| Speed Drift with Temperature | ±1 % |
| Speed Trim | ±2 Hz |
Input / Output
| Supply | 12 V DC (8 – 15 V DC) Nominal |
| 24 V DC (16 – 32 V DC) Nominal | |
| Polarity | Negative Ground (Case Isolated) |
| Power Consumption | <50 mA + actuator current |
| Maximum Actuator Current | 4 A |
| Maximum Actuator Current | Load on generator, 40 K Ω |
| Generator Frequency Sensing | Minimum sensing 1 V AC RMS MAX 260 V AC |
Physical
| Dimension | See Section 3 |
| Weight | 0.75 lbf [0.34 kgf] |
| Mounting | Any Position, Vertical Preferred |
Reliability
| Vibration | 5 g, 20 – 500 Hz |
| Shock | 20 g peak |
| Testing | 100 % Functional Testing |
Environmental
| Ambient Temperature | -40 to 185 °F [-40° to 85 °C] |
| Relative humidity | up to 100 % |