Shop
-
Transfer Switch with enclosure
GCU-10/DSP-10 Kit | Generator Control Unit
- Helps to notify the operator the generator status.
- Universal LED Graphic Interface, Displays Generator Status and Failures
- Programmable Engine & Generator Controls Adapts Easily To Any Type Generator Set.
- Waterproof Front Panel With UV Protection
- Provide IDLE control For Elec. Governors
Call for Quote for international purchases!
SKU: GCU10DSP-10 -
Transfer Switch with enclosure
GCU-100 | Generator Control Unit
- Micro-Processor Auto Control & Protection
- Three Sets of High Illuminating LED Display Suitable for Indoor and Outdoor Use
- Full Function Modularized Design for Easy Installation
- All settings are recorded into the internal (EEPROM) and protected from erasure even without battery
- Easy to Understand Graphical Warning Signals
Call for Quote for international purchases!
SKU: GCU100 -
Leroy Somer AVR
Leroy Somer AVR R438 | Original
Fuse: F1on X1,X2.10A;slow-250V
- Voltage sensing : 5 VA isolated via trans- former • 0-110 V terminals = 95 to 140 V • 0-220 V terminals = 170 to 260 V • 0-380 V terminals = 340 to 520 V for other voltages, a transformer should be used.
- Voltage regulation ± 0.5%
- Normal or rapid response time via jumper ST2 (see below)
- Voltage adjustment via potentiometer P2 or apply a DC voltage of ± 1 V on the terminals of the external potentiometer
- Current sensing: (parallel operation): input S1, S2 intended for 1 C.T. Š 2.5 VA cl1, secondary 1A (optional)
- Quadrature droop adjustment via potentio- meter P1
Call for Quote for international purchases!
SKU: R438 -
Leroy Somer AVR
Leroy Somer AVR R448 | Original
- Voltage regulation ± 0.5%
- Short circuit capability: 3 x Irated for 10 seconds (AREP or PMG excitation)
- Voltage sensing: 95 to 140 volts (50/60 Hz) or 170 to 260 volts (50/60 Hz) or 340 to 520 volts (50/60 Hz)
- Response time: Normal (1 sec) for ± 20% voltage variation or Rapid (0.3 sec) for ± 20% voltage variation
- Remote voltage adjustment range of: ± 5%
Call for Quote for international purchases!
SKU: R448 -
Leroy Somer AVR
Leroy Somer AVR R449 | Original
The regulator includes:
- A main terminal strip (10 terminals)
- A secondary terminal block (5 terminals)
- A frequency selection terminal block (3 terminals) – A quadrature droop potentiometer
- A voltage potentiometer
- A stability potentiometer
- A maximum excitation potentiometer
- A sensing selection jumper ST1 (single/3-phase with an external module)
- A response time jumper ST2 – A frequency selection jumper ST3 – An external voltage setting jumper ST4 – A LAM (load adjustment module) jumper ST5
- From R449 Version E number 10,000, this jumper will be removable.
- A selecti
Call for Quote for international purchases!
SKU: R449 -
Leroy Somer AVR
Leroy Somer AVR R450 | Original
The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers.
- Operating temperature: – 30°C to + 65° C. – Storage temperature: – 55°C to + 85°C.
- Shocks on the base: 9 g depending on the 3 axes.
- Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g.
Call for Quote for international purchases!
SKU: R450 -
Leroy Somer AVR
Leroy Somer R250 | Original
- Power Input: AC 80-140V (50 / 60Hz)
- Maximum output: DC 90V / 6A / 10S
- Detection voltage input: AC 115V
- Voltage regulation rate: ≤ ± 1% External voltage trimming 1K / 2W potentiometer ± 10%
- Voltage regulation +/- 0.5% at steady state and constant speed
Call for Quote for international purchases!
SKU: R250 -
Speed Controls
Load Sharing & Synchronizing | Speed Controls
The GAC provides a complete line of analog modules for generator sets. Module functions include load sharing, synchronizing, voltage regulation, speed ramping, voltage matching and a large assortment of analog modules to interface with other brands of controls such as Woodward, Cummins, CAT, etc.
All Electric Sensing / Accurately Measures True Power / Load Anticipation and Droop Adjustment / Small Compact Size
Call for Quote for international purchases!
SKU: LSSS -
Magnetic Pickups
M16 x 1.5 Threaded | MPS
GAC’s Magnetic Speed Sensors are a rugged and economic solution for detecting engine speed. Sturdier than plastic sensors and outperforming semiconductor-type devices at high temperatures, GAC’s epoxy encapsulated sensors are unaffected by dust and dirt. Multiple sizes and customized configurations are available.
Call for Quote for international purchases!
SKU: M16X15T -
Basler AVR, Marathon AVR, Mecc Alte AVR
Mecc Alte AVR SR7-2G (SR-7) | Original
- Sensing Input: Terminal 1,2 3,4 5,6 Can be connected to Y or 220~480VAC Single Phase 50/60HZ.
- Power Input:50~280VAC (1,2) 50/60HZ.
- Output Voltage: Maximum 90VDC @ 220VAC Harmonic Wave. Output Current: Continuous 6A Maximum 8A for 10 sec.
Call for Quote for international purchases!
SKU: SR72G -
-
Analog Speed Controls
Military Products | Speed Controls
The SLC100 electronic governor, DOD part number 98-19539, controls the generators electrical load by adjusting engine speed, it controls generator voltage, not speed. This variable speed operation results in low noise, signifi cantly reduces fuel consumption and extends engine life.
Call for Quote for international purchases!
SKU: MPS -
Magnetic Pickups
MSP6710 | Magnetic Pickup
4.86 in [123 mm] Thread Length • Military-Style Connector • Same as MSP678 except with Mating Connector EC1100 (Straight) • Stainless
- -65 ºF to +255 ºF (-54 ºC to +107 ºC) Operating Temperature
- Available for hazardous location installation (not certified)
- Produces electrical frequency
- Requires no energizing circuit from control
- Used on all GAC’s electronic speed controllers
Call for Quote for international purchases!
SKU: MSP6710 -
Magnetic Pickups
MSP6720 | Magnetic Pickup
3.86 in [98 mm] Thread Length • 1 ft [0.3 m] Harness • Flying Leads • Aluminum Clear Anodized
- -65 ºF to +255 ºF (-54 ºC to +107 ºC) Operating Temperature
- Available for hazardous location installation (not certified)
- Produces electrical frequency
- Requires no energizing circuit from control
- Used on all GAC’s electronic speed controllers
Call for Quote for international purchases!
SKU: MSP6720 -
Magnetic Pickups
MSP6723 | Magnetic Pickup
3.13 in [79 mm] Thread Length • 3 in [76 mm] Harness • Automotive Connector • Stainless
- -65 ºF to +255 ºF (-54 ºC to +107 ºC) Operating Temperature
- Available for hazardous location installation (not certified)
- Produces electrical frequency
- Requires no energizing circuit from control
- Used on all GAC’s electronic speed controllers
Call for Quote for international purchases!
SKU: MSP6723 -
Magnetic Pickups
MSP6723C | Magnetic Pickup
3.13 in [79 mm] Thread Length • 3 in [76 mm] Harness • Automotive Connector • Same as MSP6723 with Mating Harness CH1206 • Stainless
- -65 ºF to +255 ºF (-54 ºC to +107 ºC) Operating Temperature
- Available for hazardous location installation (not certified)
- Produces electrical frequency
- Requires no energizing circuit from control
- Used on all GAC’s electronic speed controllers
Call for Quote for international purchases!
SKU: MSP6723C -
Magnetic Pickups
MSP6724 | Magnetic Pickup
3.45 in [88 mm] Thread Length • 3 in [76 mm] Harness • Automotive Connector • Aluminum Gold Anodized
- -65 ºF to +255 ºF (-54 ºC to +107 ºC) Operating Temperature
- Available for hazardous location installation (not certified)
- Produces electrical frequency
- Requires no energizing circuit from control
- Used on all GAC’s electronic speed controllers
Call for Quote for international purchases!
SKU: MSP6724 -
Magnetic Pickups
MSP6724C | Magnetic Pickup
3.45 in [88 mm] Thread Length • 3 in [76 mm] Harness • Automotive Connector • Same as MSP6724 with Mating Harness CH1206 • Aluminum Gold Anodized
- -65 ºF to +255 ºF (-54 ºC to +107 ºC) Operating Temperature
- Available for hazardous location installation (not certified)
- Produces electrical frequency
- Requires no energizing circuit from control
- Used on all GAC’s electronic speed controllers
Call for Quote for international purchases!
SKU: MSP6724C -
Magnetic Pickups
MSP6728C | Magnetic Pickup
3.19 in [81 mm] Thread Length • 6.25 in [159 mm] Harness • Packard Connector • Same as MSP6728 with Mating Connector Kit EC1350 • Stainless
- -65 ºF to +255 ºF (-54 ºC to +107 ºC) Operating Temperature
- Available for hazardous location installation (not certified)
- Produces electrical frequency
- Requires no energizing circuit from control
- Used on all GAC’s electronic speed controllers
Call for Quote for international purchases!
SKU: MSP6728C -
Magnetic Pickups
MSP6729 | Magnetic Pickup
2.7 in [69 mm] Thread Length • 6 ft [1.8 m] Shielded Cable • Flying Leads • Stainless
- -65 ºF to +255 ºF (-54 ºC to +107 ºC) Operating Temperature
- Available for hazardous location installation (not certified)
- Produces electrical frequency
- Requires no energizing circuit from control
- Used on all GAC’s electronic speed controllers
Call for Quote for international purchases!
SKU: MSP6729